Search keywords:

product name, product type, model number,
test method, manufacturer, technique, application

Pressure Impulse Test Stand

BACK
Share

Standards:

SAE HS-806 SAE oil filter test procedure. ISO 4548-5 Methods of test for full-flow lubricating oil filters for internal combustion engines. Part 5: Test for cold start simulation and hydraulic pulse durability.

Applications:

It is suitable for lubricating oil filters, hydraulic oil filters and fuel oil testers, including spin-on type and cartridge type filters.
 

Product Information:

Pressure Impulse Fatigue Test Stand makes use of modern hydraulic control valve technology to provide a test stand that is simple to operate, accurate, and flexible. The Impulse Test Stand is designed to test spin-on and cartridge type filter assemblies for their resistance to fatigue failure within their envelopes.
 
Technical Parameters:

1. Oil Hydraulic Circuit

Items Parameters
Frequency range Square wave: 0-3Hz; Sine wave: 0-5Hz
Pressure range 0-6900kPa(0-1000psig)
Pressure control Servo valve with closed-loop PID control
Oil temperature range Ambient temperature- 140℃(284℉)
Temperature control Automatic PID control, ±2℃
Oil tank volume 225L(60 gallon )
Oil tank and oil pipe material Stainless steel

2. User interface, Controller and data acquisition
Items             Parameters
CPU             Dell OptiPlex w/ Intel Core™ processor
Operation system             Microsoft Windows 7
User interface             22’’ LCD, keyboard and mouse
APP software             Customized LabView, graphical display
Data output             Test report output in the form of forms and graphs, xlsx format

3. Application requirements
Items              Parameters
Power              480 Vac/3Ph/ 60Hz/40A (International voltage applicable )
Cooling water              12 lpm (3 gpm) @ 30℃ (85 ℉)
Operation temperature              10-40 ℃(50-104℉)
 

Leave Message