NewsInformation Center
Home>News > > How to prepare the test specimens for the Oxygen Index test?

How to prepare the test specimens for the Oxygen Index test?

2023/09/25

Share: 

Share
The Oxygen Index test is a testing method used to evaluate the burning properties of materials. Before performing an oxygen index test, you need to prepare appropriate test samples. The following are general steps for preparing oxygen index test samples:
 
1. Material selection:
    -Determine the type of material you want to test, e.g. plastic, fabric, etc.
    - Select the appropriate sample size and shape based on the testing standard or your testing purpose.
 
2. Sample preparation:
    - Cut the sample to obtain the desired size and shape. Depending on the test requirements, rectangular or strip samples are usually used.
    - Use an appropriate tool (such as a knife or scissors) to ensure the cut edges are flat and smooth.
 
3. Sample processing:
    - The sample surface should be clean and free of contamination. Make sure the sample surface is free of grease, dust, or other contaminants.
    - For meltable materials (such as plastics), ensure that the surface of the sample is flat with no obvious bumps or unevenness.
Oxygen index Tester
4. Sample fixation:
    - Secure the sample to the test device. The test device is usually a vertical combustion device and the sample should be placed vertically.
    - Ensure that the specimen is securely fastened to avoid movement or deformation during testing.
 
5. Preprocessing (optional):
    - For some materials, pre-treatment may be required, such as removal of surface protective film or chemical treatment. This depends on your testing requirements and material characteristics.
 
6. Sample quantity:
    - Determine the number of samples you need to test. Usually, it is recommended to test multiple samples and calculate the average to get more accurate results.
 
7. Safety measures:
    - Ensure appropriate safety measures are taken before preparing samples. This may include wearing appropriate personal protective equipment such as gloves, goggles and protective clothing.
 
8. Sample identification:
    -Identify each sample so that results can be properly recorded and identified after testing.
 
After preparing the sample, you can place the sample into the oxygen index testing equipment for testing. Be sure to follow testing standards and equipment operating guidelines to ensure accurate and repeatable test results. Based on the test results, you can evaluate the material's combustion behavior and evaluate its safety and compliance in specific applications.

Previous: What are the ici pilling test methods?
 N e x t   : What does BFE stand for medical?