Flame retardant tester for floor covering fabrics testing method
2024/03/25
Compliant with standards:
BS 4790; ISO 6925; BS 6307
Testing method:
1. Hot metal nut method BS 4790: Stainless steel nuts are heated to 900 ℃ in a muffle furnace, and the test sample is placed in a testing box. The clamp ring is placed on the sample using a crucible clamp, and the heated nut is placed in the center of the clamp ring. After 30 seconds, the nut is removed, and measurements can be taken to evaluate the spread of fire points on the sample.
2. Polymerization plate method: it is recommended to put the test box in the laboratory fume hood, place the humidified sample on the movable base in the test box, place the metal disk with a circular trimming on the sample, place the polymer plate in the center of the sample for ignition, and conduct measurement to evaluate the combustion effect after the flame is extinguished.
Previous: surface combustion tester for plush fabrics main parameters
N e x t : automotive interior material droplet characteristics tester parameters