NewsInformation Center
Home>News > > T114 Automotive Interior Material Atomization Tester Operation Steps

T114 Automotive Interior Material Atomization Tester Operation Steps

2025/01/06

Share: 

Share
T114 Automotive Interior Material Atomization Tester is suitable for high-temperature volatile atomization tests of automotive interior materials such as dashboards, knobs, seat cushions, floor leather, plastic particles, carpets, leather, adhesive products, ceiling materials, etc.
 
As a modern technology enterprise integrating R&D, manufacturing, sales, training, and services, Standard International Group (HK) Limited is committed to delivering more testing instruments to the market, providing testing instruments for textiles, leather, combustion, automotive interior and exterior trims, material environmental climate aging, etc., and non-standard customization is also acceptable. Targeted tests can be carried out according to customer requirements before purchase to ensure that the purchased instruments are applicable.
 
Measuring methods:
 
Weight method:
 
DIN 75201-B, ISO 17071, DIN EN 14288-B, ISO 6452-B, SAE J1756, PV 3015, GME 60326-A, GMW 3235-B, TSM05036-B, D45 1727
 
Gloss method/reflection method:
 
DIN 75201-A, DIN EN 14288-A, ISO 6452-A, PV 3015, PV 3920, TSM05036-B, D45 1727
 
Haze method:
 
DIN 75201-A, HES D6508-95, MS 300-54

T114_副本.jpg
 
Operation steps:
 
1. First: prepare the accessories and test samples
 
2. Place the prepared sample in the fogging cup
 
3. Prepare a piece of aluminum foil, put it in the balance to weigh, and record the value
 
4. Place the aluminum foil and glass plate on the top of the fogging cup
 
5. Set the cycle parameters of the low-temperature control box
 
6. Set the host temperature and time parameters
 
7. Start the instrument, reach the timing time, take out the aluminum foil from the workstation, put it in the balance again to weigh, and record the value
 
8. After the test, measure the fogging value or weight of the glass plate or aluminum foil, and compare it with the data before condensation, so as to obtain the fogging and volatilization characteristics of the sample.

Previous: Parameters and reference standards of paper and cardboard compression strength t