How to extend the service life of the cold and thermal shock test chamber?

2022/11/24

Share: 

Share
Cold and thermal shock test chamber test chamber using the overall combination of structural form, both test chamber is located in the upper high temperature, located in the lower low temperature chamber, located in the rear of the refrigeration unit cabinet and located on the left side of the rear panel of the electrical control cabinet (system) is composed. This way the box covers an area of small, compact, beautiful appearance, the refrigeration unit is placed in an independent unit box, in order to reduce the vibration of the refrigeration unit operation, noise on the impact of the test chamber, while facilitating the installation and maintenance of the unit, the electrical control panel is placed on the left side of the test chamber to facilitate the operation of the operation.
 
Cold and thermal shock test chamber to extend the life of the trick
cold and thermal shock test chamber
1, the condenser is stuck with dust will make the compressor high pressure switch jump off and generate false alarms, therefore, the monthly vacuum cleaner will be used to vacuum the condenser cooling mesh attached to the dust or use a hard brush brush after the machine is turned on, or use the high-pressure air nozzle to blow the dust clean;
 
2, the ground around the body and bottom should be kept clean at all times to avoid large amounts of dust inhaled into the unit to produce accidents or reduce the performance of the equipment;
 
3, open and close the door or take samples from the test chamber, can not make it touch the door seal;
 
4, once a year to check the core of the test chamber - refrigeration system, check whether there is leakage of copper pipes, the joints, interfaces have no blame for the leakage, if any, please notify the manufacturer;
 
5, cold and thermal shock test chamber humidifier and water tank should be cleaned frequently to avoid scale, affecting the distribution of steam, generally every time you do a test to clean a timely exclusion of scale is conducive to extending the life of the humidification tube to ensure smooth water flow; in the cleaning of the use of copper brushes scrubbing, and then cleaned with water;
 
6, the distribution room should be cleaned and overhauled more than once a year, the looseness of the node will make the whole equipment in a dangerous working condition, lightly burned components, heavy fire, alarm and life safety;
 
7, wet and dry ball gauze often check, when the gauze becomes hard or unclean should be replaced in a timely manner, it is recommended to replace once every 3 months;
 
8, the water pipeline is easy to plug easy to leak devices, need to regularly check whether there is a leak plugging the phenomenon, if there is, please promptly exclude or notify the manufacturer;
 
9, the humidifier water storage should be replaced once a month to ensure clean water, smooth water flow;
 
10, when the test product time to take the product, must be in the shutdown state and staff must wear a good dry, electricity, moisture-resistant gloves to take the product.
 
Standard International Group (HK) Limited is a professional enterprise engaged in the production of testing equipment and instruments. QINSUN Instrument has always been: "integrity is gold, service is the guarantee, quality is the development" for our company's business purposes, and constantly improve and improve product quality and service, to provide users with more comprehensive instrument application of the overall solution, to dare to innovate and strive for the first spirit for you.